Zoo Med
Zoo Med Environmental Control Center RT-1000
From $179.95 was
Out of stock
Buy more, pay less
Each, for the whole order. Change the quantity below and the total follows.
A thermostat, humidistat, and lighting timer in one unit. The RT-1000 gives each of its six outlets its own job, from dimming a basking lamp to switching a fogger and running day and night lights, so one controller can run a whole enclosure.
Six outlets, each with a set function
Proportional dimming heat plus on and off heating or cooling
Humidify or dehumidify from the included humidity probe
Day and night settings, timers, and temperature alarms
Up to 1,000 W combined, within each outlet's rating
Part number RT-1000
Description
- 6 outlets
- 2 temperature probes
- 1 humidity probe
- 1,000 W combined
- Day and night
- 1 year warranty
A planted or tropical enclosure can need a basking lamp, a second heater, a UVB fixture, and a mister, each with its own control. The RT-1000 handles them from one box, with separate day and night targets for temperature and humidity and its own lighting schedule. You program it on a wired LCD handset, and it keeps its settings in memory.
At a glance
- Model
- RT-1000
- Outlets
- 6, each with a set function
- Temperature probes
- 2 included
- Humidity probe
- 1 included
- Total load
- 1,000 W combined; individual outlets have lower limits
- Programming
- Wired LCD handset, settings kept in memory
- Alarms
- Programmable temperature alarms
- Warranty
- 1 year, from Zoo Med
What each outlet does
Outlet | Function | Controlled by | For example |
|---|---|---|---|
1 | Proportional dimming heat | Temperature probe 1 | A dimmable incandescent or halogen basking lamp |
2 | On and off heating or cooling | Temperature probe 2 | A second heater (HEAT) or a cooling device (COOL) |
3 | Humidify or dehumidify | Humidity probe | A fogger or mister (HUMI), or a fan (DEHUMI) |
4 | Programmable timer, two on and off periods a day | Time | Equipment that runs morning and evening |
5 | Daytime timer | Day and night schedule | A UVB fixture or daylight lamp |
6 | Nighttime timer | Day and night schedule | Night equipment that gives no visible light |
Outlets 5 and 6 alternate: when the day outlet switches off, the night outlet comes on.
Matching your equipment
Zoo Med lists it as working with a wide range of habitat gear, on the right outlet:
Incandescent basking lamps and halogen heat lamps that can be dimmed
Mercury vapour lamps, on a non-dimming outlet
Compact fluorescent, T5, and T8 fixtures, and LED lighting
Ceramic heat emitters and under-tank heaters
Automatic misting systems and ultrasonic foggers, such as the Zoo Med Repti Fogger
Cooling fans and other cooling devices
Setting it up
List the heat, light, and humidity equipment you want to run, and match each to an outlet. Add up the watts and check them against the total and each outlet's limit in Zoo Med's manual.
Place the controller somewhere dry outside the enclosure, away from spray, condensation, and heat, on its stand or the wall mount.
Fix temperature probe 1 at the spot the dimming heat should hold, and probe 2 where the second heater or cooler should be measured. Keep both off direct contact with a heater.
Fix the humidity probe somewhere typical of the enclosure, out of direct spray unless Zoo Med's instructions allow it.
Plug each device into its outlet.
Connect the handset and enter the day and night temperature and humidity targets, then the timer outlets and lighting schedule.
Set the temperature alarm limits.
Check each outlet responds, compare the readings, and watch the first few cycles before adjusting.
An alarm is no replacement for a look at the enclosure and a check with a separate thermometer now and then.
What's included
Controller
Stand
Wired LCD handset
Handset wall mount
2 temperature probes
1 humidity probe
Zoo Med instructions
Useful with it
Sale
Sale
Questions
Can I run it from my phone?
No. There is no Wi-Fi or app; you program it on the wired handset.
Can it run UVB lighting?
Yes, on a timer outlet such as outlet 5. Keep UVB lamps and their ballasts off the dimming outlet unless they are made to be dimmed.
Does it remember settings after a power cut?
Yes, settings are kept in memory. Still check the controller and your equipment after an outage.
| Part number | RT-1000 |
|---|---|
| Brand | Zoo Med |
| Shipping weight | 4 lb |
| Shipping box | 8 x 8 x 4 in |
Box size and weight are the packed carton, for shipping only, not the size of the item itself.
Shipping
Parcels across Canada and the US are priced at checkout from the packed boxes. Pallets and freight we price by hand, usually within one business day, and you pay nothing until you have seen the total. Pickup in Calgary is free.
Returns
14 day returns on eligible unused stock items, return shipping paid by the customer. Built-to-order goods are covered by the construction warranty rather than by returns. Restocking Fees Apply for returns
Warranty
One year warranty on the construction of anything we build.
Questions
Ask about it
Anything this page does not answer. We will get back to you as soon as we can, and good answers go up here for the next person.
More in Humidity, misting, and cooling
Sale
Sale
Sale
SaleExo Terra
Exo Terra 300 W Dimming & Pulse Proportional Thermostat - PT2461
$84.95 was $94.99
Only 3 left
Sale
Sale
Sale